ADVANZE 1

Product Overview

Emergency T5 Modules with Optimisation Link


The ADVANZE-1 range of modules are designed to run T5 lamps in emergency operation. The module can size is designed to fit in slim gear trays associated with linear lamps. The lamp range has increased with the use of the Mackwell Optimisation Link™.

Related Downloads

Download File

Related Downloads

Download File

ADVANZE 1 Technical Specifications

Specifications

Supply voltage230 V

Supply frequency50/60 Hz

Supply current (max)58 mA

Power factor0.35

Ambient temperature (ta)0 to +50°C

Max case temperature (tc)60°C

Conductor size0.5 - 1.5mm²

Battery charge current205 mA

Battery discharge current0.9 to 1.05 A

Battery charge voltage7.2 to 9.0 V

Battery discharge voltage5.4 to 8.3 V

Emergency duration3 hours

Recharge period24 hours

Weight of control gear142 g

Features
Switch Mode Power Supply
Mackwell patented Switch Mode Power Supply provides total short circuit protection, regulated output and complies with all relevant standards.

Ballast Delay Relay
All versions are fitted with an additional relay to switch off the power to the HF ballast during emergency lighting test.

Voltage Sensing Circuit
The AC power supply is sensed so that switching occurs at between 60% and 85% of the nominal mains supply.

Indicator
The LED indicator is illuminated when a charge is flowing to the cells. Flexible 1x0.6mm high temperature orange and pink leads connect the indicator to the module. The indicator requires a 8mm hole.

Lamp Optimisation Link
The selection of the link alters the circuitry within the module thus enabling the module to run the widest range of lamps often with increased lamp performance.

Deep Discharge Protection
The inverter module incorporates deep discharge protection (DDP), to prevent damage to the batteries caused by deep discharge and possible subsequent reverse cell polarity.
Technology Options
Standard
For applications where self-testing is not required or suitable, the non-AutoTest® option provides the same quality and performance expected of Mackwell products, without the AutoTest® feature.
Relevant Standards
  • EN 61347-1
  • EN 61347-2-3
  • EN 61347-2-7
  • EN 60598-2-22
  • BS 5266-1
  • EN 62034
  • EN 62386
  • ICEL 1004
Notes
Caution
Lamp wires should be kept to a minimum length (High Voltage - 500mm max length from terminals marked *). Not suitable for use with amalgam lamps. Charge batteries for 24 hours before commissioning. Do not insulation test this product. Reversing battery polarity will cause damage.

Image Preview

ADVANZE 1 Product Ranges

Standard
Order Codes Description
9001523 ADVANZE 1 54W 6C Module

Key Features

  • Specially designed for use with T5 lamps
  • For linear and circular lamps
  • Low Profile 28 x 28 mm section, 250 mm length
  • Maintained 5 pole ballast switching
  • Switch Mode Power Supply runs cooler than traditional iron core transformer
  • Cathode heating provides ideal thermionic emission
  • Sinusoidal HF operation
  • Featuring the Mackwell Lamp Optimisation Link™
  • 3 hour duration

Enquire Today

For more information, please call us on +44 (0) 1922 458 255 or send us a message below.


First Name *
Last Name *
Telephone Number *
Email Address *
Message *
I would like to opt in to receive marketing communications via: